Aller directement au contenu principal

Rédiger un PREreview

Non-Invasive Photonic System for Disease Screening: Fingerprinting Exhaled-Breath Metabolites

Publié
Serveur de preprints
Preprints.org
DOI
10.20944/preprints202609.1976.v1

Compact, label-free optical transducers are attractive for real-time exhaled-breath screening. We report the characterization and classification performance of a low-power photonic elastic-backscatter sensing system (the Dr. T system) that interrogates injected gas mixtures with a 635 nm, <1 mW coherent diode-laser beam and records the back-scattered light on a two-dimensional silicon position-sensing detector (PSD) as a time series of intensity I and centroid coordinates (x, y) at 10 Hz. Seven calibration data sets were acquired in a sealed 0.11 L chamber—five disease-linked metabolite mixtures in a normal-air balance (CKD, SIBO, cystic fibrosis, COPD, heart disease), a healthy base-gas control, and an ambient control (19 records). Regression showed the beam-deflection axis (y vs x) to be a linear, reproducible common-mode signature of injection flow (slopes 0.18–0.24; R2 up to 0.98), whereas the optical response versus concentration (|I| vs C) is species-specific across a >20-fold slope range, constituting an optical fingerprint. A physically motivated feature space with Mahalanobis classification separated the four diseases carrying substantive metabolites at 100% leave-one-run-out recall; overall seven-class accuracy was 78.9%. Decisively, every substantive-metabolite disease was well separated from a base-gas control undergoing an identical chamber-pressure rise (D = 4.8–13.5), demonstrating that discrimination is driven by molecular optical signatures rather than common-mode pressure. The sensor can detect, discriminate, quantify and classify metabolite mixtures in vitro; signal-to-contrast enhancement for low-cross-section analytes, humidity compensation and radiometric calibration are identified as translation priorities.

Vous pouvez rédiger un PREreview de Non-Invasive Photonic System for Disease Screening: Fingerprinting Exhaled-Breath Metabolites. Un PREreview est une évaluation d'un preprint et peut varier de quelques phrases à un rapport détaillé, semblable à un rapport d'évaluation par les pairs organisé par une revue.

Avant de commencer

Nous vous demanderons de vous connecter avec votre identifiant ORCID iD. Si vous n'en avez pas, vous pouvez en créer un.

Qu’est-ce qu’un ORCID iD ?

Un ORCID iD est un identifiant unique qui vous distingue de toute personne ayant le même nom ou nom similaire.

Commencer maintenant