Aller directement au contenu principal

Rédiger un PREreview

Comparative In Vitro Degradation of Polyglycolic Acid (PGA) and Polyglactin 910 (PGLA) Sutures Under Hyperglycemic Conditions: An Integrated Mechanical, Chemical, and Morphological Study

Publié
Serveur de preprints
Preprints.org
DOI
10.20944/preprints202607.1464.v2

Diabetes mellitus affects over 537 million adults worldwide, yet the impact of hyperglycemia on absorbable suture degradation remains poorly understood. This study evaluated the in vitro degradation of polyglycolic acid (PGA) and PGLA 910 copolymer sutures under glucose concentrations of 0, 300, and 600 mg/dL over 28 days. A total of 120 sutures (60 per material) were incubated at 37°C in phosphate-buffered saline with different glucose concentrations. Mechanical properties were assessed at baseline and at 7, 14, 21, and 28 days via tensile testing. Medium pH was monitored weekly, and surface morphology was characterized by scanning electron microscopy. PGLA 910 demonstrated higher baseline strength than PGA (14.56 ± 1.11 N vs. 13.37 ± 1.00 N; p < 0.001). Both materials maintained strength during the first 7 days (p = 0.080), but progressive loss occurred from day 14 onward. At day 28 in a glucose-free medium (0 mg/dL), PGA retained only 1.12 N (8.4% of initial strength), while PGLA 910 retained 3.81 N (26.2%; p < 0.001). SEM revealed more severe surface degradation in PGA than in PGLA 910. We conclude that PGLA 910 offers superior resistance to hydrolytic degradation, making it a more suitable choice for diabetic patients when extended mechanical integrity is required. However, both materials degrade extensively within 4 weeks and are unsuitable for applications requiring support beyond 3 weeks. The strong pH–strength correlation confirms the autocatalytic nature of the degradation mechanism.

Vous pouvez rédiger un PREreview de Comparative In Vitro Degradation of Polyglycolic Acid (PGA) and Polyglactin 910 (PGLA) Sutures Under Hyperglycemic Conditions: An Integrated Mechanical, Chemical, and Morphological Study. Un PREreview est une évaluation d'un preprint et peut varier de quelques phrases à un rapport détaillé, semblable à un rapport d'évaluation par les pairs organisé par une revue.

Avant de commencer

Nous vous demanderons de vous connecter avec votre identifiant ORCID iD. Si vous n'en avez pas, vous pouvez en créer un.

Qu’est-ce qu’un ORCID iD ?

Un ORCID iD est un identifiant unique qui vous distingue de toute personne ayant le même nom ou nom similaire.

Commencer maintenant