Saltar al contenido principal

Escribe una PREreview

Sensitivity Enhancement of Dynamic Full-Field Optical Coherence Tomography Using Ratio-Free Detection and Partial-Field Illumination for Retinal Organoid Imaging

Publicada
Servidor
Preprints.org
DOI
10.20944/preprints202605.0067.v1

Time-domain dynamic full-field optical coherence tomography (D-FFOCT) is a powerful label-free imaging modality that enables functional visualization of cellular activity in living tissues with subcellular resolution. However, its sensitivity remains a major limitation for imaging highly scattering three-dimensional (3D) biological models such as retinal organoids, where incoherent background and inefficient optical flux distribution reduce dynamic contrast and limit imaging depth. In this work, we introduce a ratio-free optical configuration for time-domain D-FFOCT that enables continuous tuning of the sample-to-reference field ratio while minimizing photon losses and suppressing parasitic reflections. This polarization-based architecture allows optimal redistribution of optical flux according to sample scattering conditions and improves sensitivity under both power-limited and dose-limited conditions. Compared with conventional non-polarizing beam splitter configurations, the proposed approach provides a √ 2-fold (3 dB) sensitivity improvement through optical optimization alone. In addition, we investigate for the first time the use of partial field illumination (PFI) in time-domain D-FFOCT to reduce incoherent background arising from multiple scattering. In retinal organoids imaged at 120 µm depth, PFI yields up to a 14.5-fold (23.2 dB) increase in dynamic signal sensitivity, while preserving functional contrast. When combined, ratio-free detection and PFI provide a cumulative sensitivity improvement of 20.5-fold (26.2 dB). These gains enable improved visualization of photoreceptor precursor organization, rosette structures, and Müller glial cell dynamics in both 3D retinal organoids and 2D cell cultures. This work establishes a practical framework for sensitivity optimization in D-FFOCT and expands its potential for functional imaging, disease modeling, and live-cell monitoring in complex biological systems.

Puedes escribir una PREreview de Sensitivity Enhancement of Dynamic Full-Field Optical Coherence Tomography Using Ratio-Free Detection and Partial-Field Illumination for Retinal Organoid Imaging. Una PREreview es una revisión de un preprint y puede variar desde unas pocas oraciones hasta un extenso informe, similar a un informe de revisión por pares organizado por una revista.

Antes de comenzar

We will ask you to log in with your ORCID iD. If you don’t have an iD, you can create one.

What is an ORCID iD?

An ORCID iD is a unique identifier that distinguishes you from everyone with the same or similar name.

Comenzar ahora