## Summary

GuideTouch is a standalone wearable obstacle-avoidance aid: two vertically aligned VL53L5CX multizone time-of-flight sensors (combined vertical field of view 90°) feed an ESP32, which drives four vibrotactile motors arranged across the shoulders and upper chest to indicate obstacle direction. The device adds a centrifugal self-cleaning optical cover and an audible alarm for locating it if dropped; the reported cost is approximately 100 USD and total weight under 500 g. The evaluation has two parts: a haptic perception study with 22 participants seated at a laptop, identifying script-generated vibration patterns (average recognition 92.9% for single- and double-motor patterns in one subgroup, 78.4% across all 15 patterns in the other), and a preliminary study with 14 visually impaired users reporting 93.75% recognition of primary directional cues. Requirements were derived from interviews with 28 visually impaired people. I read this as a late-breaking report and calibrate my expectations accordingly: the concerns below are not about the volume of experimentation, but about the distance between what the experiments measure and what the title and abstract claim, and about one headline number whose basis cannot be reconstructed.

## Strengths

- The project starts the right way: requirements were elicited from interviews with 28 visually impaired people, and the hazard categories they named (head-level obstacles, drop-offs and open manholes, thin poles and fencing) are concrete and user-grounded rather than assumed.

- Visually impaired users were actually involved in the evaluation. This is rarer in this literature than it should be, and it distinguishes this work from systems evaluated only on sighted stand-ins.

- The haptic study is reported with full confusion matrices, and the negative results are in the open: complex three- and four-motor patterns are recognised at only 42–65%, and the two participants whose poor device contact degraded accuracy are analysed rather than silently dropped.

- Two design details show a lived understanding of the users' reality: the self-cleaning optical cover (a blind user cannot see that a lens is dirty) and the drop alarm (a blind user cannot look for a dropped device). These are small things that papers written at a distance from users rarely think of.

- The deployment philosophy is right for the user group: fully standalone, no phone, no cloud, commodity components, roughly 100 USD.

## Major concerns

1. Every reported experiment validates the display channel, while the title and abstract claim an obstacle-avoidance device validated with visually impaired users. In both studies, participants sat still and identified vibration patterns generated by a script; the sensors were not in the loop, no obstacle was present, nobody walked, and no avoidance behaviour was measured. The paper's own conclusion concedes the findings were "obtained with first-time users and under static conditions" (§4). What has been demonstrated is that users can learn to decode the device's tactile language — a necessary component result, and a good one — but the abstract's framing ("preliminary experiments with 14 visually impaired users showed 93.75% recognition", in a paper titled Obstacle Avoidance Device) invites readers to file that number as evidence about avoiding obstacles, which it is not. Please scope the title-level and abstract claims to what was evaluated (haptic pattern recognition under static conditions), or add even a small integrated evaluation in which visually impaired users walk a route with the full system running.

2. The sensing half of the system has no experimental results at all, including against the hazards the authors' own interviewees ranked highest. The paper never states the device's maximum detection range. There is no measurement of detection accuracy, missed detections, or false alarms at any distance, for any obstacle type. The coverage statement in §2.2 (knee-level and head-level obstacles detectable from 50 cm for a 170 cm wearer, ~30% zone occupancy, 4 cm linear size at 1 m) is a geometric assertion, not a measurement. Meanwhile the categories the 28 interviewees identified as their major undetected dangers — drop-offs, open manholes, stairs, thin poles and fencing (§1) — receive no test of any kind, and transparent obstacles (glass doors and panels, a standard failure mode for optical ranging) are not discussed. A minimal detection benchmark would close most of this gap: a set of representative obstacles (including a pole, a glass panel, and a descending step edge) at several distances, reporting detection and miss rates per zone. Without it, the reader knows the device can speak but not whether it can see.

3. The headline figure for the visually impaired group, 93.75%, has no reconstructable basis, and the abstract's selection of numbers is one-sided. Section 3.4, the only description of the visually impaired study, is a single paragraph: no trial count, no number of patterns presented, no repetitions, no training protocol, no per-participant data, no statistics. The denominator behind 93.75% cannot be recovered from the paper (the value is arithmetically consistent with a very small number of trials, which makes reporting the counts more important, not less). The abstract and §4 give 93.75% while §3.4 gives 93.7%. Separately, the abstract presents 92.9% as the recognition accuracy for single- and double-motor patterns, but §3.3 shows this is the average of Group B only (11 participants, simple patterns); Group A's average across all 15 patterns is 78.4%, and that figure does not appear in the abstract. Please report the visually impaired study's protocol and raw counts, reconcile the two versions of its headline number, and let the abstract carry the all-pattern figure alongside the simple-pattern one.

4. Proximity is claimed as communicated but never specified; only direction is described. The abstract states that the actuators convey "proximity and direction", yet §2.3 describes only side/direction activation (the motors on the side of the obstacle vibrate; multiple zones activate multiple motors). No mapping from distance to any signal parameter (intensity, frequency, duration, repetition rate) is given anywhere. For an avoidance aid, direction without distance leaves the user unable to distinguish an obstacle at three metres from one at thirty centimetres. Relatedly, no end-to-end timing is reported: the only temporal quantity is the 0.1 s sensor sampling interval (§2.3), while the perception study used 3-second pattern presentations (§3.2) — how the deployed device sequences patterns in time while a user is walking is not described. Please specify the proximity encoding (or correct the abstract), and describe the temporal behaviour of the feedback during walking.

## Minor points

1. No confidence intervals or effect sizes are reported anywhere in the paper; the visually impaired study reports no statistics at all. Even for a preliminary study, per-participant results for the 14 users would cost little and say much.

2. Field-of-view figures disagree within §2.2: each sensor is stated to have a 65° diagonal FoV, but the zone-size formula in the same section uses FoV = 60°.

3. The pattern set's composition is inconsistent: §3.1 describes Group A's set as single, double, and triple combinations (4 + 6 + 4 = 14), while Table 1 contains 15 patterns including the four-motor combination discussed in §3.3. Please reconcile text and table.

4. Three participant groups appear (28 interviewees, 22 perception-study participants, 14 visually impaired testers) with no statement of how they relate or overlap; the 22 are never explicitly identified as sighted, which must be inferred from the laptop-GUI procedure.

5. I could find no ethics approval or informed consent statement in the arXiv text, although the visually impaired group includes participants as young as 16. If approval and consent were obtained, the statement should be added; if the published version carries it, the preprint should be updated to match.

6. There is no code or data availability statement, and no firmware, PCB files, or bill of materials is released. For a device whose ~100 USD cost is part of its contribution, releasing the design files would let others verify both the cost and the results.

7. The self-cleaning mechanism's costs are reported honestly (70 dB at head level; battery life drops from 12 h to 4 h while rotating) but are not weighed in the discussion. A sentence on when cleaning is expected to run (on demand? periodically?) and how the noise interacts with the environmental hearing blind pedestrians rely on would complete the picture.

## Overall assessment

This is a thoughtfully designed device from a team that clearly spends time with its users, and the haptic-channel evaluation it reports is solid as far as it goes. The paper's problem is one of framing and missing denominators rather than of effort: a component validation is presented in the language of a system validation, the sensing half of the system carries no measurements, and the number most likely to be quoted from the abstract cannot be traced to any reported count. All three are fixable without new hardware — a small detection benchmark, a full protocol for the visually impaired study, and claims trimmed to the evidence. I hope the authors do this, because the underlying work, honestly scoped, is the kind of assistive technology this field needs more of.