Transmission of SARS-CoV-2 Considering Shared Chairs in Outpatient Dialysis: A Real-World Case-Control Study
- Posted
- Server
- medRxiv
- DOI
- 10.1101/2021.02.20.21251855
Background
SARS-CoV-2 is primarily transmitted through aerosolized droplets; however, the virus can remain transiently viable on surfaces.
Objective
We examined transmission within hemodialysis facilities, with a specific focus on the possibility of indirect patient-to-patient transmission through shared dialysis chairs.
Design
We used real-world data from hemodialysis patients treated between February 1stand June 8th, 2020 to perform a case-control study matching each SARS-CoV-2 positive patient (case) to a non-SARS-CoV-2 patient (control) in the same dialysis shift and traced back 14 days to capture possible exposure from chairs sat in by SARS-CoV-2 patients. Cases and controls were matched on age, sex, race, facility, shift date, and treatment count.
Setting
2,600 hemodialysis facilities in the United States.
Patients
Adult (age ≥18 years) hemodialysis patients.
Measurements
Conditional logistic regression models tested whether chair exposure after a positive patient conferred a higher risk of SARS-CoV-2 infection to the immediate subsequent patient.
Results
Among 170,234 hemodialysis patients, 4,782 (2.8%) tested positive for SARS-CoV-2 (mean age 64 years, 44% female). Most facilities (68.5%) had 0 to 1 positive SARS-CoV-2 patient. We matched 2,379 SARS-CoV-2 positive cases to 2,379 non-SARS-CoV-2 controls; 1.30% (95%CI 0.90%, 1.87%) of cases and 1.39% (95%CI 0.97%, 1.97%) of controls were exposed to a chair previously sat in by a shedding SARS-CoV-2 patient. Transmission risk among cases was not significantly different from controls (OR=0.94; 95%CI 0.57 to 1.54; p=0.80). Results remained consistent in adjusted and sensitivity analyses.
Limitation
Analysis used real-world data that could contain errors and only considered vertical transmission associated with shared use of dialysis chairs by symptomatic patients.
Conclusions
The risk of indirect patient-to-patient transmission of SARS-CoV-2 infection from dialysis chairs appears to be low.
Primary Funding Source
Fresenius Medical Care North America; National Institute of Diabetes and Digestive and Kidney Diseases (R01DK130067)